CONV-DCDC-40KW-IMMQ-06-F (40kW)
CONV-DCDC-40KW-IMMQ-06-F (40kW)
-
ï„‘In stock
Delivered within 3 weeks
Power: 40 kW max
Cooling: Air
Isolation: Non isolated
Voltage low range: 430V-630V
Voltage high range: 630V-820V
In addition
Starter kit
Ideal for facilitating the commissioning of your DC DC converters
Features
- Programmable smart DC/DC converter allowing regulation according to voltage, current or power, input or output
- Buck/boost transition controlled by CAN command
- Operations controlled through insulated CAN 2.0B
- Parallelization of DC/DC modules for higher power delivery (in current source mode only)
- Air cooling
Applications
- Fuel cell power
- Battery systems
- Super capacitors
- Chargers
- Loads
- Motors
Architecture
Aerospace
Van
Truck
Backhoe
Excavator
Stationary
Accessories LV
Accessories HV
Energy Store
Fuel Cell
H2 Tank
Ciso DCDC HV-LV
Convy DCDC HV-HV
LV Accessories
Fuel Cell
H2 Storage Tank
HV Battery Pack / 400V
Ciso DCDC HV-LV 24V / Up to 6 kW
Convy DCDC HV-HV / 400V output
LV accessories
Drive motors
Inverter
Battery Pack / 350-850 V
CISO DC/DC HV-LV - 24V
LV Equipments / 24-48 V
HV Equipments
Batteries HV
Fuel Cell / H2 Tank
Ciso DCDC HV-LV / 24-48 V
Convy DCDC HV-HV
LV Accessories
HV Batteries
Inverter / Drive Motor
Ciso DCDC HV-LV / 48 V
Electrical network
Transformer
Batteries / Energy Storage
Charging Port / 200-850 V
Battery Pack / 800 V
Convy DCDC HV-HV
Convy DCDC HV-HV
ELECTRICAL
SPECIFICATIONS
CONV-DCDC-40KW-IMMQ-06-F
High voltage range
630 V – 820 V
Low voltage range
430 V – 630 V
Rated output current
150 A
Maximum power
40 kW
Efficiency
Up to 98%
Supply voltage
9V - 13.5V for (12V option) and 18V - 28V for (24V option)
Supply consumption
30 W (Max)
Regulation modes
Current/ Voltage/ Power
Safety features
HVIL, OTP, OCP, OVP, UVP
Isolation
No
Galvanic insulation
3.0 kV (Insulation resistance 2 MΩ)
COMMUNICATION
SPECIFICATIONS
CONV-DCDC-40KW-IMMQ-06-F
Protocole
CAN 2.0B / 500 kbits/s
Frames period
100 ms
COOLING
SPECIFICATIONS
CONV-DCDC-40KW-IMMQ-06-F
Cooling type
Forced Air Cooling by built-in Fans
Operating temperature
-40 °C to +55 °C
Flow rate
268 cm3/h